Torqcut Start-up procedure

From i3Detroit
(Redirected from Bridgeport CNC Mill)
Jump to: navigation, search

The CNC mill requires compressed air so the shop air compressor has to be running.
If no one else needs compressed air, don't forget to turn off the compressor after you're done. There's a leak somewhere in the system.

  • Power up the CNC mill with the power switch on the back panel. Clockwise is "on", counterclockwise is "off".
Power Switch - from rear of CNC mill


Main power switch in the "on" position.

Power Switch - "on" position.


Main power switch in the "off" position.

Power Switch - "off" position.


  • Valve to shop compressed air at CNC mill.
Valve that connects CNC mill to shop air compressor.


Compressed air valve closed.

Valve that connects CNC mill to shop air compressor in the "closed" position.


  • Lift red air valve on CNC

You'll find the machine's air valve on the left side of the mill. Just raise it.

Air valve on CNC mill.



Machine air valve in the closed - down - position

Air valve on CNC in closed position.



Machine air valve in the open - up - position

Air valve on CNC in opened position.



Next thing you want to do before you start using the mill is check that its fluid levels are where they're supposed to be. The first thing to check is the lubricant level.

Location of the lubricant reservoir.



There's a level marked on the duct tape.

The lubricant reservoir.



If the lubricant level's where it's supposed to be then check the coolant level.

Location of the coolant reservoir.



There are filter screens on both sides of the coolant tank that can be removed to check coolant level.
The screens have handles but they tend to be pretty grimy so be warned.

A closer view of the coolant reservoir.



Coolant reservoir open.



To recap, power on, air on - shop compressor on if it's off - raise air valve, check lubricant level, check coolant level.